Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Chinese Journal of Biotechnology ; (12): 1672-1678, 2020.
Article in Chinese | WPRIM | ID: wpr-826810

ABSTRACT

To investigate the detection threshold of Treponema pallidum specific antibody method by chemiluminescent immunoassay (CLIA) in Siemens ADVIA Centaur XP for Syphilis serological test, and compare with the results derived from CMIA, TP-WB and TPPA method. The result can serve as reference for the application of CLIA. In total 30 887 samples screened by Treponema pallidum specific antibody method were collected by Abbott architect i2000 CMIA from July 2018 to July 2019 in Yanda Hospital of Hebei Province. We selected 153 patients with the ratio of sample absorbance to critical value (S/CO) of 1-9 by CMIA screening of Treponema pallidum specific antibody as the research objects. The reverse sequence of syphilis serological detection was adopted, and TP-WB and TPPA were used as the confirmation methods respectively. MedCalc software was used to analyze the results of ROC curve, and the cut-off value was obtained. Chi square test was used to test the difference significance of counting data. The detection results of Treponema pallidum specific antibody in the same batch of serum samples were unequal by different methods. There was no significant difference between CLIA method and TPPA method, but significant difference between CLIA method with TP-WB method and CMIA method was found. TPPA test results and TP-WB test results were taken as gold standards, ROC curve analysis showed that the best diagnostic cutoff value of CLIA method was 4.01 and 16.06, respectively, and the area under the curve was 0.961 and 0.838. The suggested cutoff value of CLIA method is quite different when using different syphilis serological test methods as the gold standard, Therefore, when the S/CO value determined by CLIA is between 1.00 to 16.06, TP-WB method should be recommended as the first choice in laboratory serological test for recheck and confirmation to avoid clinical misdiagnosis.

2.
Rev. cuba. med. trop ; 50(2): 93-95, Mayo-ago. 1998.
Article in Spanish | LILACS | ID: lil-629281

ABSTRACT

Se estudia la posibilidad de detectar anticuerpos al VIH-1 mediante un estuche de Immunoblotting, en un papel de 125 muestras conocidas de sangre seca colectadas en papel de filtro y su correspondiente muestra de suero. No se apreciaron diferencias en los patrones de bandas con ambos tipos de muestras, así como en la sensibilidad y especificidad, donde se alcanzaron cifras del 100 %, lo que permitió concluir que la muestra de sangre tomada en papel de filtro puede ser empleada para la detección de anticuerpos al VIH-1 por el sistema DAVIH-BLOT y puede ser conservada a 4 ºC por 30 semanas.


The possibility of detecting HIV-1 antibodies by an inmunoblotting kit is studied in a panel of 125 known specimens of dried blood spotted on filter paper and their corresponding serum samples. No differences were observed in the patterns of bands with both types of samples or in the sensitivity and specificity, where 100 % figures were attained, allowing to conclude that the blood specimen taken on filter paper may be used for the detection of HIV-1 antibodies by the DAVIH-BLOT system and may be kept at 4 ºC during 30 weeks.


Subject(s)
Humans , HIV Antibodies/blood , AIDS Serodiagnosis/instrumentation , AIDS Serodiagnosis/methods , Blotting, Western/instrumentation , Blotting, Western/methods , Filtration/instrumentation , Paper , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL